Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Virol Plus ; 2(3): 100098, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: covidwho-2301093

RESUMEN

Here we describe a retrospective clinical evaluation of the QIAGEN artus® SARS-CoV-2 Prep&Amp UM RT-PCR assay that detects SARS-CoV-2 RNA without the need for a nucleic acid eluate extraction procedure. Using Roche SARS-CoV-2 RT-PCR on the cobas® 8800 platform as a reference standard, a total of 225 confirmed SARS-CoV-2 positive and 320 negative nasopharyngeal swabs in viral transport media, were used to evaluate the artus® assay. Using the RT-PCR cycle threshold as a semi-quantitative marker of viral load, an assessment of over 370,000 SARS-CoV-2 RT-PCR positive results was used in the design of the reference positive specimen cohort. The viral load of all reference positive specimens used in the evaluation was a unique and accurate representation of the range and levels of SARS-CoV-2 positivity observed over a 13-month period of the COVID-19 pandemic. The artus® RT-PCR detects the presence of SARS-CoV-2 RNA, an internal control, and the human RNase P gene to ensure specimen quality. The diagnostic sensitivity of artus® was 92.89% with a specificity of 100%. To assess the analytical sensitivity, a limit of detection was performed using the 1st WHO NIBSC SARS-CoV-2 international standard, recording a 95% LOD of 1.1 × 103 IU/ml. The total invalid rate of specimens was 7.34% due to a lack of detectable RNase P (Ct >35). The artus® SARS-CoV-2 Prep&Amp UM RT-PCR assay is a new rapid RT-PCR assay, which may be considered to produce acceptable levels of diagnostic sensitivity and specificity whilst potentially halving the laboratory processing time.

2.
Clin Lab Med ; 42(2): 161-191, 2022 06.
Artículo en Inglés | MEDLINE | ID: covidwho-2130433

RESUMEN

The COVID-19 pandemic has led to the rapid development of a plethora of molecular diagnostic assays with real-time polymerase chain reaction (RT-PCR) at the forefront. In this review, we will discuss the history and utility of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) molecular diagnostics and the associated current and future regulatory process in Europe. We will assess the performance characteristics of a range of the most common SARS-CoV-2 molecular tests currently used in Europe with a focus on as rapid molecular platforms, stand-alone RT-PCR kits, the role of low-throughput and high-throughput end-to-end testing platforms, and the rapidly evolving field of SARS-CoV-2 variant of concern identification.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Europa (Continente)/epidemiología , Humanos , Pandemias , Patología Molecular , SARS-CoV-2/genética
3.
Journal of clinical virology plus ; 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-1940324

RESUMEN

Here we describe a retrospective clinical evaluation of the QIAGEN artus® SARS-CoV-2 Prep&Amp UM RT-PCR assay that detects SARS-CoV-2 RNA without the need for a nucleic acid eluate extraction procedure. Using Roche SARS-CoV-2 RT-PCR on the cobas® 8800 platform as a reference standard, a total of 225 confirmed SARS-CoV-2 positive and 320 negative nasopharyngeal swabs in viral transport media, were used to evaluate the artus® assay. Using the RT-PCR cycle threshold as a semi-quantitative marker of viral load, an assessment of over 370,000 SARS-CoV-2 RT-PCR positive results was used in the design of the reference positive specimen cohort. The viral load of all reference positive specimens used in the evaluation was a unique and accurate representation of the range and levels of SARS-CoV-2 positivity observed over a 13-month period of the COVID-19 pandemic. The artus® RT-PCR detects the presence of SARS-CoV-2 RNA, an internal control, and the human RNase P gene to ensure specimen quality. The diagnostic sensitivity of artus® was 92.89% with a specificity of 100%. To assess the analytical sensitivity, a limit of detection was performed using the 1st WHO NIBSC SARS-CoV-2 international standard, recording a 95% LOD of 1.1 × 103 IU/ml. The total invalid rate of specimens was 7.34% due to a lack of detectable RNase P (Ct >35). The artus® SARS-CoV-2 Prep&Amp UM RT-PCR assay is a new rapid RT-PCR assay, which may be considered to produce acceptable levels of diagnostic sensitivity and specificity whilst potentially halving the laboratory processing time.

4.
J Infect ; 83(1): 84-91, 2021 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1198892

RESUMEN

OBJECTIVES: SARS-CoV-2 emerged in South Asia in 2019 and has resulted in a global pandemic. Public Health England (PHE) Manchester rapidly escalated testing for SARS-CoV-2 in the highest COVID-19 incidence location in England. The results of the PHE Manchester SARS-CoV-2 surveillance during the first wave are presented. METHODS: Retrospective data were collected for patients fitting the PHE SARS-CoV-2 case definition from 11th February to 31st August 2020. Respiratory tract, tissue, faecal, fluid and cerebrospinal (CSF) samples were tested for SARS-CoV-2 by a semi-quantitative real-time reverse-transcription PCR. RESULTS: Of the 204,083 tests for SARS-CoV-2, 18,011 were positive demonstrating a positivity of 8.90%. Highest positivity was in nasal swabs (20.99%) followed by broncheo-alveolar lavage samples (12.50%). None of the faecal, fluid or CSF samples received were positive for SARS-CoV-2. CONCLUSIONS: There was a high incidence of SARS-CoV-2 patients in the North-West of England during the first UK wave of the Covid-19 pandemic. Highest positivity rate was in nasal specimens suggesting this is the optimum sample type within this dataset for detecting SARS-CoV-2. Further studies are warranted to assess the utility of testing faecal, fluid and CSF samples. Rapid escalation of testing via multiple platforms was required to ensure prompt diagnosis and isolate infected cases to reduce transmission of the virus.


Asunto(s)
COVID-19 , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo , Asia , Inglaterra/epidemiología , Humanos , Pandemias , Estudios Retrospectivos , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo/genética , SARS-CoV-2
5.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artículo en Inglés | MEDLINE | ID: covidwho-1005937

RESUMEN

Nucleic acid amplification tests (NAATs) are the primary means of identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and isolation resources and allow rapid therapeutic interventions. We evaluated the analytical and clinical performance characteristics of the Xpert Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2; other infectious coronavirus species, including SARS-CoV; and 85 nasopharyngeal swab specimens positive for other respiratory viruses, including endemic human coronaviruses (hCoVs). Clinical performance was assessed using 483 remnant upper- and lower-respiratory-tract specimens previously analyzed by standard-of-care (SOC) NAATs. The limit of detection of the Xpert test was 0.01 PFU/ml. Other hCoVs, including Middle East respiratory syndrome coronavirus, were not detected by the Xpert test. SARS-CoV, a closely related species in the subgenus Sarbecovirus, was detected by a broad-range target (E) but was distinguished from SARS-CoV-2 (SARS-CoV-2-specific N2 target). Compared to SOC NAATs, the positive agreement of the Xpert test was 219/220 (99.5%), and the negative agreement was 250/261 (95.8%). A third tie-breaker NAAT resolved all but three of the discordant results in favor the Xpert test. The Xpert test provided sensitive and accurate detection of SARS-CoV-2 in a variety of upper- and lower-respiratory-tract specimens. The high sensitivity and short time to results of approximately 45 min may impact patient management.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Neumonía Viral/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Automatización de Laboratorios/métodos , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Niño , Preescolar , Infecciones por Coronavirus/virología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Pandemias , Neumonía Viral/virología , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA